7FA COMBUSTION TURBINE

GE’s revved-up 7FA natural gas turbine takes a bow | GE Reports


GE Frame 7FA General Electric PG7241FA. Dry Low NOx. Gas Turbine 5.1.2 Combustion System. Dry Low NOx combustion system GE Frame 7FA Author: Larry Rayman Keywords State-of-the-art turbine parts. PSM designs and manufactures fully OEM-compatible airfoils and DLN combustion components for the GE 6B, 7B/EA, 7FA and 9E (combustion The Simulator had a specific configuration for GE Frame 7FA+ (Model 7241) combustion turbines each with a rated output of 185 MWe gross under standard conditions.
GE’s revved-up 7FA natural gas turbine takes a bow | GE Reports

PIC Turbine Services’ Record Setting Completion of Outages | PIC


We inspect the compressors in four locations from the inlet, the combustion section, the turbine and the exhaust. On the 7FA every stage of the compressor is inspected. CTG~GTG -0809-01,02,03 04 FOUR (4) X GE 7FA 60 Hz COMBUSTION GAS TURBINE GENERATOR SETS The Camelot Technologies Group International, Inc. (CTG) -17231 Camelot A gas turbine, also called a combustion turbine, is a type of internal combustion engine. It has an upstream rotating compressor coupled to a downstream turbine, and
PIC Turbine Services’ Record Setting Completion of Outages | PIC

GE 7FA Heavy Duty Gas Turbine: Ecomagination


Colectric's CT-SPIN® program manages a pool of combustion (CI) and hot gas path (HGP) parts for GE 7FA combustion turbine Table 6. 7FA.05 version combustion model experience. Turbine Section The turbine section of the 7FA.05 version capitalizes on the recent 7FA.04 Hot Gas Path advancements. (1) Never Used 160 MW GE 7FA Turbine Generator Ocotillo, California Project (1 Unit) Memphis, Tennessee (Ocotillo Combustion Turbine Material Shipped Direct (MSD))
GE 7FA Heavy Duty Gas Turbine: Ecomagination

Appendix A Power Plant Design Information


Combustion The 7FA.05 gas turbine will employ the proven DLN2.6 combustor. The combustor has more than 15 million hours and 400,000 starts of operational experience. Pratt Whitney Power Systems (PWPS) has designed the combustion liner, flow sleeve and transition piece for the combustion system for the Frame 7FA+e gas turbine. For example, a typical power plant operating two new 7FA gas turbines with a single steam turbine — using what’s known as a “combined cycle configuration
Appendix A Power Plant Design Information

oject Description


GE's 7FA turbine uses the company's DLN-2 combustion system. GE 7FA inlet system, generator and turbine sections in the early stages of General view of the GE 7FA parts for all major aeroderivative and heavy industrial gas turbine technologies, including 7FA refurbished hot gas path capital parts. Our goal is to help power producers Two (2) General Electric 7FA Combustion Turbine and Hydrogen Cooled Generator Two (2) Fired Three Pressure Heat Recovery Steam Generator (HRSG) with Stack
oject Description

GE Frame 7FA


Gas Turbine Systems Gas Turbine Base-mounted PG7241 (FA) 60 Hz gas turbine including: • Modulating IGV Combustion System • Dry Low NOx combustion system Like most OEM’s, the 7FA’s turbine inlet temperature has been increased GT26 50-Hz engine and GT24 60-Hz engines are both sequential combustion turbines, which Eddy Current Inspections of the S-0, S-1 and S-2 stator vanes on Frames 5, 7EA and 7FA, to detect cracking that has lead to stator vane failures on numerous gas turbines.
GE Frame 7FA

Frame 7FA/+/+E Experience – gas turbine engine repairs


The plant is owned and operated by the Entegra Power Group, and consists of eight GE Frame 7FA combustion turbines with inlet air fogging, eight Alstom heat recovery The new turbine uses the DLN 2.6 combustor—a proven combustion system with more than 14 million hours of Some of the first new 7FA turbines are planned for the proposed 200 ppmvd @15% O2 for a GE 7FA combustion turbine. 2 Thermal NOX forms in the high temperature area of the combustor. Thermal NOX increases exponentially
Frame 7FA/+/+E Experience - gas turbine engine repairs

Startup and Shutdown Emissions from


Colloquial Names for these Combustion Turbine Models 7FA 7FB 7H 9F 9FA 9FB 9H General Electric (GE) Energy Frame 7FA combustion turbine-generator (CTG), equipped with dry low NOx combustors for the control of NOx, and an evaporative cooler for • Two General Electric GE 7FA, gas combustion turbines (maximum fuel consumption rating of 1,671 million British thermal units per hour (mmBtu/hr)) connected to an
Startup and Shutdown Emissions from

Flexible Design for Gas Turbine Generation – Burns McDonnell


Its improved efficiency and higher output will result in less fuel consumption and lower emissions on a MW-hr basis than currently available 7FA gas turbines (7FA.03 location. ft myers plant combustion turbine procedure number combustion turbine-004 rev. n ct offline water wash valving tag-out procedure Abstract. This report contains an update on the most recent application of the EPRI life management system designed for the evaluation of combustion turbine hot
Flexible Design for Gas Turbine Generation - Burns  McDonnell

ProEnergy Services | Experience Our Energy


New Members: ryac7jotfo joined 23 minutes ago. Donna Cheatwood joined 36 minutes ago. KrompeliOoSc joined 56 minutes ago. mikprz9nke joined 57 minutes ago. Gas Turbine: 7FA/60Hz/171MW. General Electric PG7241FA. Dry Low NOx. Gas Turbine 5.1.2 Combustion System. Dry Low NOx combustion system. Combustion system features + Combustion Parts compatible with 6B (models through 6581), 7EA, 7FA us with access to nearly 100 advanced gas turbines.
ProEnergy Services | Experience Our Energy

Pratt Whitney: Power Systems – IGT Parts Repairs – 7FAe


1st Buckets 2nd Buckets 3rd Buckets 1st Nozzle 2nd Nozzle 3rd Nozzle 1st Shroud Blocks 2nd Shroud Blocks 3rd Shroud Blocks Combustion Caps Combustion Liners The facility was designed to incorporate two General Electric 7FA combustion turbine-generators coupled with two heat recovery steam generators (HRSG) and a common steam Frame 7FA/+/+E Components Repaired W501D5-D5A (SGT6-3000E) W251B-B12 Steam Turbines Final inspection on Frame 7FA combustion caps.
Pratt  Whitney: Power Systems - IGT Parts  Repairs - 7FAe

GE 7FA Gas Turbine Promotional Video from the 1990's – Power Plant


The performance and efficiency of the 7FA gas turbine can translate to increased Increased fuel flexibility with self-calibrating combustion system to handle MISTRAS Group Develops On-line Monitoring System for GE 7FA Combustion Turbines Monday March 15, 2010 – 10:48 AM EDT Source: GlobeNewswire News Releases I found a promotional video of GE's 7FA combustion turbine dating back to the 1990's. This video is great and wanted to share with the Power Plant
GE 7FA Gas Turbine Promotional Video from the 1990's - Power Plant